When should temporary wiring be removed?
Temporary wiring must be removed immediately upon completion of construction or the purpose for which it was installed [590.3(D)].
What NEC code covers temporary wiring?
Temporary wiring must meet the requirements of the National Electrical Code (NEC) and be installed and maintained by qualified persons that apply safe work practices in compliance with industry standards. Article 590 of the Code provides minimum requirements for installing temporary electrical power and lighting.
What is a NEC code article?

Do you understand the general requirements for all installations? Article 110 of the National Electrical Code (NEC) covers the general requirements for the examination and approval, installation and use, access to, and spaces about electrical equipment.
What type cable shall be permitted to be installed in a branch circuit raceway in a temporary underground installation?
(2) Type SE cable shall be permitted to be installed in a raceway in an underground installation.
Are extension cords considered temporary wiring?
Extension cords, factory-manufactured or assembled at work sites and shops, are considered temporary wiring.

Can Romex be used for temporary lighting?
Romex is a trade name. The electrical classification is non-metallic sheath cable. If used in accordance with the applicable codes and its construction is water and flame resistant it may be used for temporary lighting.
Does temp power need to be grounded?
In addition to providing for equipment grounding, the electrical system itself must be grounded, and it is ordinarily accomplished by connecting the neutral circuit conductor to a grounding electrode by means of a grounding electrode conductor at the service.
Is the NEC mandatory?
While the NEC is not itself a U.S. law, the NEC is commonly mandated by state or local law. Where the NEC is adopted, anything less is illegal.
Can you use Romex for temp power?
Can you run more than one wire through a hole?
The Answer. According to the National Electrical Code, you can have 4 12/2 nonmetallic sheathed cables through a single bored hole that is fire- or draft-stopped using thermal insulation, caulk, or sealing foam, or where proper spacing is not maintained for more that 24 in.
Are surge protectors considered extension cords?
The higher amperage cords are used for the more heavy duty equipment. Higher amperage cords are often necessary to carry power longer distances. Surge protectors differ from extension cords in a variety of ways. You may find surge protectors that give you extra length and extension cords with surge protection.
What is the maximum number of extension cords you can connect to one another?
The Maximum number of extension cords you can connect to one another is three. Orange outlets are only to be used for heavy equipment such as the compactor.
What are the code for electrical wiring?
The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association.
How often must temporary wiring be supported?
One of the requirements for permanent wiring, and thus for temporary wiring, was the need for adequate support. Article 336-18 stated that cable must be secured in place at intervals not exceeding 4.5 feet (1.37 m) and within 12 inches (305 mm) from every cabinet, box, or fitting.
What is the main purpose of NEC?
The NEC (the National Fire Protection Association’s NFPA 70) is a widely-adopted model code for the installation of electrical components and systems. Its purpose is to safeguard persons and property from hazards arising from the use of electricity (NEC 90.1(A)).